A218 DRIVEFLEX® VFD RHW-2 with 2 Control Pairs

LUTZE Driveflex A218
Application
  • Shielded multi-conductor cable for VFD, Servo and Motor applications to connect power from drives to motors
  • Cable design for harsh industrial environments and operating conditions with high noise levels
  • XLPE thick wall insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs
  • Compliant with NFPA 79 for wiring of industrial machinery
  • TC-ER-JP for use with cable trays without conduit, which can reduce material and labor costs
  • WTTC – wind turbine tray cable rating for use in wind power generation
  • Dry, damp or wet conditions
Characteristics
  • Flexible XLPE conductor design
  • Non-wicking fillers
  • Effective dual layer shield for EMC compliance
  • Specially formulated jacket for oil resistance and easy strip design
  • Crush impact resistant
  • Gas/vapor-tight sheath per UL1277 
  • Low capacitance cable
  • Sunlight resistant
  • Flame retardant
  • Direct burial
  • Talc free and silicone free
Part number Description No. of conductors incl. ground OD - Ø ca. mm OD - Ø ca. inches Weight Lbs/Mft Copper Lbs/Mft
A2181604 AWG 16 (26/30)
2 TSP AWG18 (19/30)
4 + 2 pairs
17.8 0.699 278 113
A2181404 AWG 14 (41/30)
2 TSP AWG16 (26/30)
4 + 2 pairs
19.3 0.760 330 149
A2181204 AWG 12 (65/30)
2 TSP AWG16 (26/30)
4 + 2 pairs
20.2 0.795 388 187
A2181004 AWG 10 (105/30)
2 TSP AWG14 (41/30)
4 + 2 pairs
23.6 0.930 553 261
A2180804 AWG 8 (168/30)
2 TSP AWG14 (41/30)
4 + 2 pairs
27.7 1.070 778 364
Voltage: 600V UL TC-ER-JP
1000V Flexible VFD Servo Cable 90C, 1000V 105C AWM,
1000V WTTC
Temperature: -40°C - +90°C static
Bending radius: 6 x cable OD
Conductor marking: Black with white numbers and one green/yellow ground
Approvals: UL Type Flexible Motor Supply,
Flexible VFD Servo Cable,
TC-ER-JP, WTTC, DP-1
Meets NEC 336, 392 Class I,II Div. 2 and Class I Zone 2 per NEC 501, 502, 505
AWM 20886
c(UL) TC, CIC FT4
UL 1277
P-07-KA130021-MSHA
RoHS, REACH
Construction: AWG conductor
Flexible fine wire stranded tinned copper conductors for improved electrical characteristics and reduced oxidation
XLPE insulation, Wet/Dry
(4C RHW-2, 2 Pairs XHHW-2)
Shielded with foil tape, tinned copper braid with 80% optical coverage, and drain wire
Oil resistant PVC jacket
Black jacket RAL 9005
Capacitance Impedance
Part number Mutual (pF/ft) Ground (pF/ft) Mutual (Ohms) Ground (Ohms)
A2181604 12.6 25.0 83.2 49.8
A2181404 17.1 31.7 71.9 45.7
A2181204 18.0 35.2 75.5 35.4
A2181004 20.0 36.2 61.2 42.3
A2180804 20.8 38.9 66.5 33.9